Printing version
Capnograph MPR 6/1-03 TRITON allows monitoring of breathing rate and EtCO2, FiCO2 levels in patients of all age groups (from neonates to adults).
Features:
- The device is based on the unique Unicap TM technology of laser capnometry.
- Use of laser has allowed creating a capnometry sensor free of moving mechanical parts thereby increasing accuracy and reliability of measurements.
- This capnograph does not need calibration and/or verification with standard gases. Passage of time and usage do not affect factory calibration of the sensor.
- Small volume of measuring cuvette decreases the sample flow to 50 milliliters per minute.
- Self-test hardware inbuilt in MPR 6/1-03 TRITON allows efficient control over the key components functioning, detects the status of sensors in the autonomous regime.
- MPR 6/1-03 has an efficient multi-stage sample dehumidifying system. The device also has an in-built self-cleaning program.
|
|
Specification:
Capnography Channel:
- Effective sample dehumidifying system
- Automatic measurement results correction if nitrous oxide is present
- Measurement range – 0-10% (0-80 mmHg)
- Display modes: concentrations in % or partial pressure in mmHg
- Measurement accuracy: 0.2 % in the 0-5% range, 0.4% in the 5-10% range
- Breathing rate 10-200 per minute
- Displays capnogramm, EtCO2, FiCO2 breathing rate on the screen
- Adjustable alarms of high and low levels of EtCO2, and high level of FiCO2
Alarms:
- Three-tier alarm system with audible and visual alerts
- Adjustable alarms : EtCO2 , FiCO2
Data storage:
- Trends are displayed as separate graphs for all monitored parameters and alarms
- All graphs are displayed in real time in a single window
- Data is saved with 1 minute steps, and past data can be shown anytime, with the trends displayed as a table
- Basic memory volume allows saving 48 hours of measurement in 1 minute steps
- Data storage is immune to power loss
Recordable trends:
User interface:
- Color TFT screen with active backlight (the device can be used in dimmed rooms or in a car or plane)
- Display size: 6,4 inches ( 16,26 centimeters)
- Screen resolution: 640x480 pixels
- Convenient “shuttle” manipulator allows fast and convenient operation of the device
Accessories (standard set):
- CO2 measurement set (T-connector and extension line) – 5 sets
Power supply system :
- The device can be plugged into 220V – 50GHz alternating current power supply
- The device has an in-built battery
- Battery is recharged automatically
- The device can run on battery for no less than 3 hours
- A transportable (mobile) version of MPR-6/1-03 TRITON capnograph produced for car and air ambulances can work from a standard 12 volt car socket
- Power consumption: no more than 35 VA
Size and weight:
- Size : 300 x 180 x 290 mm ± 2 mm (11,811 x 7,086 x 11,417 inches ± 0,078 inches)
- Weight: no more than 5,3 kg ( 11,68 pounds) with in-built battery
|